CheckPoint has now developed a modular, scalable electric pump range
with the most efficient drive mechanism available. The FXA delivers up to 19.79
USG/H (74.91 L/H) and can reliably pump at pressures up to 10,000 PSIG
(689 BARG). For low flow applications, the FXA pump can easily achieve 0.052
USG/H (0.20 L/H). The single FXA drive mechanism accommodates several
different motors and a full range of plunger diameters from 1/8" to 1.5" and
ANY Series 1250, 1500, and LPX chemical head.
- FLOW RANGE
0 to 19.79 USG/H
(0 to 74.91 L/H)
- PRESSURE
0 to 10,000 PSIG (0 to 689 BARG)
- RELIABLE
Fewest moving components & proven CheckPoint head technology
- DURABLE
Materials and construction stand up to real world situations
- ULTRA EFFICIENT
20 - 40% efficiency improvement
|
|

additional info:
Performance Data
Sales Brochure |
MODULAR DESIGN
No other plunger pump offers such flexibility across such a wide range of flow rates and pressures. That's
because no other pump offers as many head and plunger diameter choices on a single drive. When you
switch chemicals, move the pump to a different location, or boost line pressure, the FXA will be more likely
to handle differing requirements with simple changes to the plunger and chemical head rather than switching
out to a new pump. In fact, there are seven plunger diameters available: 1/8", 1/4", 3/8", 1/2", 3/4" and 1".
INDUSTRIAL STRENGTH CONSTRUCTION
The FXA uses all 316L SS materials on wetted components, and aircraft-grade aluminum hard anodized
exterior housing to a hardness of at least HRC 51. The modular pump head design comes standard as 316L
SS (HastelloyTM, Duplex, PVC, Titanium also available). The plunger material is HastelloyTM coated with our
EverWearTM ceramic surface treatment for nearly infinite life. Wetted seals are offered in a full range of elastomers
- such as Viton® Extreme, TeflonTM and FFKM which provide excellent chemical compatibility. The
FXA chemical head employs our highly-evolved FailSafe poppet-style check valves, proven reliable over 15
years of challenging field duty around the world. This pump is appropriate for any offshore or plant conditions.
MAXIMUM RELIABILITY = MINIMUM OPERATING COST
With proven chemical head technology from our Series 1500, 1250 and LPX pumps and the most efficient
drive module available, long term reliability of the critical components is assured. The FXA is designed to
withstand harsh field conditions for many years with high accuracy, low failure rates, and no corrosion. Just
as our pneumatic products provided “order of magnitude” cost reductions in fields all over the world, our
FXA pumps deliver those same benefits in electrical applications. (For more information about CheckPoint’s
well-proven operating cost reductions, please see our website at www.cppumps.com)
STANDARD “PLUG & PLAY” PACKAGES FOR SALE OR RENTAL

Compact standard packages are now available with all components
needed to optimize the performance of the FXA, including gauges,
pipework, valves, drip pan, PRV, regulator, etceteras. Our field experience
and design know-how is your assurance that every component in
every package will work together to give you “plug & play” convenience.
In-stock, for sale or rental.
Solar-powered packages are also available. Ask about our FXA Solar
System or go online.
| |
HEAD TYPE 1250 SERIES |
HEAD TYPE 1500 SERIES |
| PLUNGER DIAMETER |
(IN) |
1/8* |
3/16 |
1/4* |
3/8 |
1/2 |
1/2 |
3/4 |
1 |
1-1/2 |
| (MM) |
3.2 |
4.8 |
6.4 |
9.5 |
12.7 |
12.7 |
9.1 |
25.4 |
38.1 |
FLOW RATE (USG/H) / (L/H) |
MAX |
0.15 |
0.31 |
0.52 |
1.20 |
2.21 |
2.21 |
5 |
8.95 |
19.79 |
| |
0.57 |
1.17 |
1.97 |
4.57 |
8.36 |
8.36 |
18.93 |
33.88 |
74.91 |
| MIN |
0.01 |
0.03 |
0.05 |
0.12 |
0.22 |
0.22 |
0.50 |
0.89 |
1.97 |
| |
0.06 |
0.12 |
0.20 |
0.45 |
0.83 |
0.83 |
1.89 |
3.37 |
7.46 |
STROKE VOLUME @ 0 PSIG DISCHARGE |
(IN3) |
0.01 |
0.02 |
0.04 |
0.10 |
0.16 |
0.16 |
0.33 |
0.53 |
1.30 |
| (CC) |
0.16 |
0.33 |
0.66 |
1.64 |
2.62 |
2.62 |
5.41 |
8.69 |
21.30 |
MAXIMUM DISCHARGE PRESSURE |
(PSIG) |
10,000 |
10,000 |
10,000 |
9,000 |
5,000 |
5,000 |
4,500 |
2,000 |
1,000 |
| (BARG) |
689 |
689 |
689 |
621 |
345 |
345 |
310 |
137 |
68 |
|
* 1/8 and 1/4 performance applies to both 1250 (adjustable packing) and LPX (non-adjustable packing) head
configurations
|
MOTOR NOTES: Recommended motor size up to 1/2 HP, 58RPM, 30:1 Ratio, 230VAC.