1250 & 1500 Series

Specifically designed for demanding chemical delivery, CheckPoint Injectors are extensively used in many industries, including:

  • Oil & Gas
  • Chemical
  • Pulp & Paper
  • Water Treatment
  • Agriculture
  • Food Processing
...and many others.

CheckPoint Chemical Injectors are pneumatically powered, positive displacement, reciprocating pumps with superior durability.

 

additional info:
Performance Data
Gas Recovery Option
Flow Curves
Gas Consumption
Certified Drawings
1250 Parts List
1500 Parts List
1250 Operating Manual
1500 Operating Manual
  pneumatic chemical injection pumps 1250 & 1500


Performance Data : 1250 & 1500

  Series 1250 Series 1500
Cycle Rate / Minute 1 0.5 - 105 2 0.75 - 85 3
Supply Pressure 20 - 200 psig (1.4 - 3.8 barg) 20 - 200 psig (1.4 - 3.8 barg)
Piston Diameter 2.50 in (64 mm) 5.00 in (127 mm)
Stroke Length 4 0.94 in (24 mm) 1.00 in (25 mm)
Weight 11 lbs (5 kg) 20 lbs (9.1 kg)
Height 12 in (305 mm) 13.5 in (343 mm)
Turndown Ratio
(max / min cycle rate)
210 113
1. Series 1250 "Short Stroke" models cycle rate / minute ranges from 1 - 210; Series 1500 "Short Stroke" models have a stroke length of 0.5 in (13 mm)
2. Series 1250 can cycle faster than the max. listed rate; not recommended for long-term use. Contact CheckPoint before operating above 105 cycles/minute.
3. Series 1500 Gas Recovery pumps have a max cycle rate / min of 65.
4. "Short Stroke" models have a stroke length of 0.5 in (13 mm)


  Series 1250 Series 1500
Plunger Diameter in 1/8 3/16 1/4 3/8 1/2 3/8 1/2 3/4 1 1 1/2
mm 3.2 4.8 6.4 9.5 12.7 9.5 12.7 9.1 25.4 38.1
Chemical Flow Rate
(us gal /hr) / (l /hr)
min 0.003 0.007 0.014 0.031 0.050 0.031 0.063 0.125 0.208 0.400
  0.013 0.027 0.052 0.118 0.189 0.118 0.247 0.473 0.789 1.514
max 0.34 0.727 1.38 3.29 5.63 2.25 3.38 9.58 15.63 29.00
  1.30 2.718 5.20 12.46 21.29 8.52 12.78 36.28 59.15 109.77
Vol / Cycle
@ 0 psig Discharge 3
in3 0.013 0.028 0.050 0.121 0.206 0.050 0.153 0.434 0.708 1.735
cc 0.207 0.453 0.826 1.978 3.380 0.826 2.505 7.113 11.597 28.432
Power Amplification Ratio   399 176 99 43 24 175 99 43 24 11
Max Discharge Pressure
@ 200 psig Supply
psig 12,000
(4)
12,000
(4)
12,000
(4)
8,689 4,800 15,000
(4)
10,000
(4)
9,000 5,000 2,200
barg 827 827 827 599 331 1,034 689 621 345 152
1. Chemical flow rate calculations are theoretical and are based on zero discharge pressure. As discharge pressure rises, cycle volume and pump speed will decrease.
2. With the Series 1500 Gas Recovery pumps, decrease maximum chemical flowrate by approx. 25%.
3. Reduce Volume/Cycle on Short Stroke models by 50%
4. Pump can exceed maximum recommended discharge pressure. A pressure relief valve, or other appropriate safety equipment, must be used with these pumps.


pneumatic pump selection chart : 1250 & 1500


 